Power is an essential commodity for the advancement of every community. The level of development of any country can be weighed on the scale "how stable her power supply is". No matter the effort the government of a country put in to ensure development of that country, in vain is the effort if there exist power instability in that country. Personally, I have  done some analysis and research, and discovered that all developed countries have stable power supply. Here in Africa, countries like Ghana, South Africa and some other countries which are progressive in terms of development, are enjoying some degree of constant power supply.
___
<p></p><h1>Introduction</h1> Power system is a network or arrangement of components designed with  for the purpose of generation, transmission, distribution and utilization of electrical energy. Electricity can be generated in different ways ranging from thermal means to hydro means, however, the main purpose of generating electricity is for consumption or utilization by country people or neighboring country. Hence, we can say that without utilization, the purpose of generation of electricity is incomplete.  This brings in the question "how does electricity generating companies ensure that consumers utilize the electric energy generated?"
___
Unlike the sick patient that has to visit a doctor in hospital before getting some treatments(services), the consumers or utilizes of electricity do not have to go directly to electricity generating companies to utilize electricity; even if there is an option of going to these companies directly, would you stay in your apartment without light? As a solution to this the electricity generating companies has to deploy a means which ensures that electrical power is readily available for the consumers. Because of the distance between electricity generating company and the potential consumers, stages has to be employed to filled in the gap between electricity generation and electricity utilization.<span style="font-size: 1rem;">This stages that fill in the gap are the transmission stations and the distribution company.<br><br>

</span><img src="https://res.cloudinary.com/drrz8xekm/image/upload/v1554599204/nkoqbyc31hf0bk8vnogz.png" data-filename="nkoqbyc31hf0bk8vnogz" style="width: 527.5px;"><span style="font-size: 1rem;" <br="">Source:[wikimedia](https://commons.wikimedia.org/wiki/File:Electricity_grid_simple-_North_America.svg)||license:[CCA 3.0](creativecommons.org)<br><br>
Depending on country, different level of voltage is generated and steeped up using transformers before transmitting. Here in Nigeria, most electricity generating companies generate voltages of magnitude 11KV and step it up to 33KV, 132KV or 330KV which are the transmission voltages.  The  transmission of such a high magnitude of voltage is to account for the losses encountered in the transmission line, this means before the voltage gets to the transmission companies, it must have dropped to some extent. All the transmission company and generating company are interconnected in a ring system, which is somewhat like a loop.
The electric power now in transmission company has not yet gotten to the consumers; so transmission company(substation) still has their own part to play in ensuring this electrical energy gets to the consumers. Transmission substation steps down the different voltages to 11KV then transmit to distribution companies(substation). The distribution companies step down the voltage further to 415V before sending it to distribution line, finally the available transformers steps down the voltage to 220V or 110V depending on country.  Power system ensures all these operations are carried  out successfully.</span><p></p><p></p><h2>Transmission Line Components</h2> Components are otherwise the subsystem of a system. So,  components of a power system implies the subsystem that make up a power system.  
<h3>Conductors</h3> Conductors are dielectrics that allow the flow of electricity with a very little resistance under a given range of frequency, of-course frequency has effect on the conductance of a dielectric. Conductors are the actual line of transmission or medium of transmission.  The over head thick non-insulated cables are among  the conductors transmission company transmits power through.  Conductor come in different form ranging from solid conductor to composite conductor.
**Solid conductors** are one thick wire which is not flexible. A better alternative is the stranded conductor which is made up of relatively tiny conductors superimposed on the other. Stranded conductor has the advantage of flexibility. Another is the composite conductor; this conductor is somewhat a stranded conductor but has being reinforce(a different material added to it for tensile strength). An example of this is the Aluminum conductor Steel Supported(ACSS); this composite conductor is made up of strings or strands of aluminium intertwined on steel for the purpose of strength, another example is the Aluminium Conductor Alloy Reinforced(ACAR).<br><br>
<img src="https://res.cloudinary.com/drrz8xekm/image/upload/v1554597822/rnydhqsqcc4h7mfsvel7.jpg" data-filename="rnydhqsqcc4h7mfsvel7" style="width: 527.5px;"><br>source:[wikimedia](https://commons.wikimedia.org/wiki/File:ACSR_and_ACCC.JPG)||license:[CC by SA 3.0](creativecommons.org)||Description: ACSR<br><br>
Bundled conductor means two or more separated conductors carrying a single phase voltage. Taking your AC source in the wall of your house as an example, you used two different wires to tap from the wall socket to your electrical extension. That is to say, you have two wires plugged in to the LIVE and two wires plugged in to the Neutral, the two separate conductors carrying one phase is simply a bundle of conductor. This has the advantage of low resistance as it increases the surface area of the path available for the flow of current. Such is also employed in transmission of extra high voltages, bundle of conductor are the six wires you see on a single support structure, each two wire is carrying a phase. In bundling, the two wires are not touching each other along the line, this helps in reducing the magnetic field. bundling also minimizes corona effect which is responsible for the humming sound heard close to active transformers 
<h3>Insulators</h3> Insulators are opposite of dielectrics. It opposes the flow of current under specified conditions. <br><br>&nbsp;<img src="https://res.cloudinary.com/drrz8xekm/image/upload/v1554597459/unspldfevpencuemnv5u.jpg" data-filename="unspldfevpencuemnv5u" style="width: 527.5px;"> <br>Source:[Maxpixel](https://www.maxpixel.net/Insulators-High-Voltage-Glass-Transmission-Line-112331)|| license:[Public domain](creativecommons.org)<br><br>
In transmission line, insulators does not only the conductors from electrically contacting the support structures, but also holds the conductor in a required position. Insulators come in different types like the suspension type, the shackle type insulators among others
<h3>Shield Wires</h3> Shield wires are made from high conducting dielectrics  and are earthed. Its function is to protect the transmission conductors in the event of lightening.  Whenever lightening bolt hits the transmission system, the shield wires provide a safe path for it to the earth. This ensures that the conductors are protected.
<h3>Support structures</h3> Support structures are the towers on which the the transmission line rest upon through the aid of an insulator. Support structure ensures that the conducting wires is far above sudden contact with human.<br><br><img src="https://res.cloudinary.com/drrz8xekm/image/upload/v1554596918/otgfgrxk0revbfziy2oj.jpg" data-filename="otgfgrxk0revbfziy2oj" style="width: 527.5px;"><br> Source:[Wikipedia](https://en.wikipedia.org/wiki/File:Romanian_electric_power_transmission_lines.jpg)||License:[CCA 2.0](creativecommons.org)<br><br>
This corresponds to safety also. Support structures comes broadly in two types which are the poles and towers. In high voltage transmission, the tower type of support structure is used. It can be self supporting(does not require extra support)  or stayed tower(requires additional support). 
<p></p><h2>Design Consideration</h2> To design a new transmission line for a community or to extend transmission of electrical energy to  remote communities, some factors has to be considered.  Electrical construction companies consider some factors before putting a new extension of transmission line on ground.
<h3>Electrical Factors</h3> Before construction a new transmission line, Engineers consider some electrical analysis like the magnitude of power generated and the expected maximum current in order to calculate the cross section of the conductor to use and even the type of conductor to use.More power means a better with a relatively bigger cross sectional area. The type of insulation to use ;  the spacing between the conductors and the resultant magnetic field due to that spacing; the[ reliability of the transmission](https://steemit.com/steemstem/@ikchris/deep-thought-reliabi-1552497914) line  and the type of earthing material to use are all considered under this. 
<h3>Mechanical Factors</h3> This deals with the mechanism of the transmission line. Before constructing a new transmission line, engineers consider things like, the maximum pressure or weight each support structure can bear, the tensile strength of the support structures and its  form of expansion of the towers under different temperatures. The best support tower to use(whether horizontal or vertical); the spacing of the different support structures and the depth of ground to dig for each location of the tower . Ways of improving the mechanical strength especially for swampy area is also considered.  Finally the mechanical factor also entails the vibration of the tower due to the force on a conductor carrying high magnitude of voltage/current.
<h3>Environmental Factor</h3>  Fault might arise in a transmission line, if such a fault arise how does it affect the environment, people living in it and even wildlife?. This factor considers such and hence, an overhead transmission line should not pass through a densely populated areas; underground system should be an option.
Transmission are not built over house roofs and people are always advises to stay clear off from transmission line towers not just because of the risk of electric shock, but also for the risk of some radiations from the high voltage carrying conductor.
Also some towers and overhead lines have the tendency of making a geographical area rough and appalling to see, this is resolved by designing a tower which blends with specific region
<h3>Economic Factor</h3> Achieving the best at the possible minimum cost makes any construction firm unique. While construction a new transmission line,  it is good to spend minimal but also build the best that can withstand pressures and vibrations <br>
<h4>Conclusion</h4> The importance of electrical power to human can not be over emphasized. Hence, electrical power is generated,transmitted, distributed and utilized, this forms a complete cycle of electrical power flow . This cycle is achieved through power system . All the stages of the cycle are important.
<h5>References</h5>
* [Electrical power generation](https://en.wikipedia.org/wiki/Electricity_generation)<br><br>
* [Electrical power transmission](http://edisontechcenter.org/Transmission.html)<br><br>
* [Electrical power distribution](https://en.wikipedia.org/wiki/Electric_power_distribution)<br><br>
* [Enviromental effect of transmssion lines](https://www.fingrid.fi/en/grid/land-use-and-environment/environmental-impacts-of-transmission-lines/)<br><br>
* [Over head power line](https://en.wikipedia.org/wiki/Overhead_power_line)<br><br>
* [The purpose of insulators in transmission line](https://www.quora.com/Why-is-an-insulator-used-in-a-transmission-line)<br><br>
* [conductors used in transmssion line](http://www.electricalpowerenergy.com/2014/02/11/types-of-conductors-use-for-transmission-line/)<br><br>
* [Composite conductor, strand and bundled conductor](https://engineeringtutorial.com/difference-solid-conductor-stranded-conductor/)
👍  , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , and 368 others
properties (23)
authorikchris
permlinkpower-system-transmi-1554599802
categorysteemstem
json_metadata{"tags":["steemstem","stemng","wafrica","electricity"],"app":"steemstem"}
created2019-04-07 01:16:51
last_update2019-04-07 01:16:51
depth0
children4
last_payout2019-04-14 01:16:51
cashout_time1969-12-31 23:59:59
total_payout_value2.428 HBD
curator_payout_value0.832 HBD
pending_payout_value0.000 HBD
promoted0.000 HBD
body_length12,256
author_reputation4,853,445,694,923
root_title"Power System: Transmission Line Components and Design Considerations "
beneficiaries
0.
accountsteemstem
weight1,000
max_accepted_payout1,000,000.000 HBD
percent_hbd10,000
post_id82,608,047
net_rshares5,723,076,473,309
author_curate_reward""
vote details (432)
@greenrun ·
ogeqk1jez
Imagine the power transmission system without the transformers! I still think the transformers are the real MVP of power transmission. We can transmit at up to 330KV in Nigeria when most generating stations can only generate at between 11KV to 16KV, imagine for a moment that there was no transformer. 
properties (22)
authorgreenrun
permlinkogeqk1jez
categorysteemstem
json_metadata{"tags":"steemstem","app":"steemstem"}
created2019-04-08 19:57:21
last_update2019-04-08 19:57:21
depth1
children1
last_payout2019-04-15 19:57:21
cashout_time1969-12-31 23:59:59
total_payout_value0.000 HBD
curator_payout_value0.000 HBD
pending_payout_value0.000 HBD
promoted0.000 HBD
body_length302
author_reputation38,837,562,295,457
root_title"Power System: Transmission Line Components and Design Considerations "
beneficiaries[]
max_accepted_payout1,000,000.000 HBD
percent_hbd10,000
post_id82,707,712
net_rshares0
@ikchris ·
without the transformer there is no way to account for the voltage drops along the transmission line,  just like I emphasized that the generating stations   steps up the 11kv  generated to a higher voltage magnitude  using some transformers.
properties (22)
authorikchris
permlinkre-greenrun-ogeqk1jez-20190408t230731200z
categorysteemstem
json_metadata{"tags":["steemstem"],"app":"steemit/0.1"}
created2019-04-08 23:07:33
last_update2019-04-08 23:07:33
depth2
children0
last_payout2019-04-15 23:07:33
cashout_time1969-12-31 23:59:59
total_payout_value0.000 HBD
curator_payout_value0.000 HBD
pending_payout_value0.000 HBD
promoted0.000 HBD
body_length241
author_reputation4,853,445,694,923
root_title"Power System: Transmission Line Components and Design Considerations "
beneficiaries[]
max_accepted_payout1,000,000.000 HBD
percent_hbd10,000
post_id82,714,113
net_rshares0
@steemitboard ·
Congratulations @ikchris! You have completed the following achievement on the Steem blockchain and have been rewarded with new badge(s) :

<table><tr><td>https://steemitimages.com/60x70/http://steemitboard.com/@ikchris/comments.png?201904070243</td><td>You made more than 200 comments. Your next target is to reach 300 comments.</td></tr>
</table>

<sub>_You can view [your badges on your Steem Board](https://steemitboard.com/@ikchris) and compare to others on the [Steem Ranking](http://steemitboard.com/ranking/index.php?name=ikchris)_</sub>
<sub>_If you no longer want to receive notifications, reply to this comment with the word_ `STOP`</sub>


To support your work, I also upvoted your post!


**Do not miss the last post from @steemitboard:**
<table><tr><td><a href="https://steemit.com/steemitboard/@steemitboard/the-steem-blockchain-survived-its-first-virus-plague"><img src="https://steemitimages.com/64x128/https://steemitimages.com/0x0/![](https://cdn.steemitimages.com/DQmYKnawrtqFCShyVvVs4QS7548eretcMUKQJc3D2f69pb9/image.png)"></a></td><td><a href="https://steemit.com/steemitboard/@steemitboard/the-steem-blockchain-survived-its-first-virus-plague">The Steem blockchain survived its first virus plague!</a></td></tr></table>

###### [Vote for @Steemitboard as a witness](https://v2.steemconnect.com/sign/account-witness-vote?witness=steemitboard&approve=1) to get one more award and increased upvotes!
properties (22)
authorsteemitboard
permlinksteemitboard-notify-ikchris-20190407t033108000z
categorysteemstem
json_metadata{"image":["https://steemitboard.com/img/notify.png"]}
created2019-04-07 03:31:06
last_update2019-04-07 03:31:06
depth1
children0
last_payout2019-04-14 03:31:06
cashout_time1969-12-31 23:59:59
total_payout_value0.000 HBD
curator_payout_value0.000 HBD
pending_payout_value0.000 HBD
promoted0.000 HBD
body_length1,418
author_reputation38,975,615,169,260
root_title"Power System: Transmission Line Components and Design Considerations "
beneficiaries[]
max_accepted_payout1,000,000.000 HBD
percent_hbd10,000
post_id82,613,772
net_rshares0
@steemstem ·
re-ikchris-power-system-transmi-1554599802-20190410t183454024z
<div class='text-justify'> <div class='pull-left'> <center> <br /> <img width='200' src='https://res.cloudinary.com/drrz8xekm/image/upload/v1553698283/weenlqbrqvvczjy6dayw.jpg'> </center>  <br/> </div> 

This post has been voted on by the **SteemSTEM** curation team and voting trail. It is elligible for support from <b><a href='https://www.steemstem.io/#!/@curie'>@curie</a></b>.<br /> 

If you appreciate the work we are doing, then consider supporting our witness [**stem.witness**](https://steemconnect.com/sign/account_witness_vote?approve=1&witness=stem.witness). Additional witness support to the [**curie witness**](https://steemconnect.com/sign/account_witness_vote?approve=1&witness=curie) would be appreciated as well.<br /> 

For additional information please join us on the [**SteemSTEM discord**]( https://discord.gg/BPARaqn) and to get to know the rest of the community!<br />

Thanks for having added <b><a href='https://www.steemstem.io/#!/@steemstem'>@steemstem</a></b> as a beneficiary to your post. This granted you a stronger support from SteemSTEM.<br />

Thanks for having used the <b><a href='https://www.steemstem.io'>steemstem.io</a></b> app. You got a stronger support!</div>
properties (22)
authorsteemstem
permlinkre-ikchris-power-system-transmi-1554599802-20190410t183454024z
categorysteemstem
json_metadata{"app":"bloguable-bot"}
created2019-04-10 18:34:57
last_update2019-04-10 18:34:57
depth1
children0
last_payout2019-04-17 18:34:57
cashout_time1969-12-31 23:59:59
total_payout_value0.000 HBD
curator_payout_value0.000 HBD
pending_payout_value0.000 HBD
promoted0.000 HBD
body_length1,203
author_reputation262,017,435,115,313
root_title"Power System: Transmission Line Components and Design Considerations "
beneficiaries[]
max_accepted_payout1,000,000.000 HBD
percent_hbd10,000
post_id82,826,823
net_rshares0